+39 331 584 7291 [email protected] Mon-Fri 8:00-17:30 (CET)
Immersion Liquid Cooling System

Immersion Liquid Cooling System

Browse technical resources about specialty optical cables, hybrid cables, waterproof patch cords, MPO/MTP, AWG WDM, 800G transceivers, testers, outdoor power cabinets, DCI, smart grid and industrial o...

  • AI Server Liquid Cooling Connector Machining

    AI Server Liquid Cooling Connector Machining

    This article shows how CNC precision machining turns designs—water blocks, water clod plates, and fine heat-dissipation features—into reliable, scalable hardware. Air can no longer keep junction temperatures in check as AI server power density climbs. AI server liquid cooling connectors are precision-engineered components manufactured from 316L stainless steel, featuring superior corrosion resistance for demanding cooling applications. Designed specifically for high-density AI computing environments, these connectors maintain excellent thermal. Are you looking for a reliable CNC machining partner for AI Server liquid cooling systems? At CAA Precision, we specialize in manufacturing high-reliability non-standard fittings, manifolds, and quick disconnects (QD) for the hyperscale data center industry. Manufactured with tight tolerances up to ±0. → Send your drawings to get engineering feedback.

    [PDF Version]
  • PoE Switch Cooling Fan

    PoE Switch Cooling Fan

    In contrast, a fan-based PoE switch contains a fan or multiple fans to ensure optimal cooling. The fan expels heat from inside the switch and releases it into the air, which enhances the speed and efficiency of heat dissipation. This cooling method. For years I've been searching for a passively cooled 16-24 port L2 managed POE switch to replace a Cisco SG110-16HP unmanaged POE switch. Seemingly impossible, the need to play with VLANs made me give up on this search and ended up buying a Netgear GS324TP. The main compromise in choosing this was. 1. I replaced them both with a Noctua NF-A4x20 PWM, which is a very quiet fan. Fan cooled models feature an integral PoE Power Splitter which provides power to the DC cooling fan as well as providing power+data for two PoE devices. NEW! NEW! NEW!Need to cut a hole in a piece of furniture and install a small case fan to vent hot air out. 3af/at device, or a ghetto not-IEEE power.

    [PDF Version]
  • Airflow direction of network rack cooling fans

    Airflow direction of network rack cooling fans

    Front-to-back airflow is the standard cooling direction used in most data center server racks. In this configuration, chilled air is drawn in from the rack's front side, flows across the internal components to absorb heat, and is expelled as warm air through the rear. After all, sealing these gaps (both within and along the sides of cabinets) often provides the greatest return on investment of any airflow management effort, both. The foundation of data center airflow management is the Hot Aisle-Cold Aisle design, where cabinets are placed in alternating rows, with IT air intakes (cold aisles) and IT air exhausts (hot aisles) each facing one another. Modern servers turn nearly all of the electrical power they consume into heat. That sounds simple, but in a dense rack the practical effect is important: every extra. Knowing the airflow of your devices helps to properly plan in the data center the direction in which each device should be rack mounted to allow for proper air cooling. This list is constantly being updated, so feel free to bookmark it.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic and telecom products

Get a Quote