Browse technical resources about specialty optical cables, hybrid cables, waterproof patch cords, MPO/MTP, AWG WDM, 800G transceivers, testers, outdoor power cabinets, DCI, smart grid and industrial o...

  • Relay protection cooling load

    Relay protection cooling load

    This report describes cold load pickup and inrush problems as they affect protective relaying applications on distribution feeder circuits and provides guidance for protective system applications. SEL time-domain technology. Thermal overload protection is a safety feature that prevents electrical equipment from overheating and getting damaged. A list of pertinent literature and recent studies is provided as well as some real life examples. This is the principle behind the ' thermal replica ' model of a motor used for overload protection. The temperature T at any instant is given by: Temperature rise is proportional to the current squared: Therefore, it can be shown that, for any overload current I, the permissible time t for this.


  • Airflow direction of network rack cooling fans

    Airflow direction of network rack cooling fans

    Front-to-back airflow is the standard cooling direction used in most data center server racks. In this configuration, chilled air is drawn in from the rack's front side, flows across the internal components to absorb heat, and is expelled as warm air through the rear. After all, sealing these gaps (both within and along the sides of cabinets) often provides the greatest return on investment of any airflow management effort, both. The foundation of data center airflow management is the Hot Aisle-Cold Aisle design, where cabinets are placed in alternating rows, with IT air intakes (cold aisles) and IT air exhausts (hot aisles) each facing one another. Modern servers turn nearly all of the electrical power they consume into heat. That sounds simple, but in a dense rack the practical effect is important: every extra. Knowing the airflow of your devices helps to properly plan in the data center the direction in which each device should be rack mounted to allow for proper air cooling. This list is constantly being updated, so feel free to bookmark it.

    [PDF Version]
  • Is the optical attenuation the same at the ports of the optical splitter

    Is the optical attenuation the same at the ports of the optical splitter

    The signal attenuation in an optical splitter is symmetrical, meaning it is the same in both directions. In fiber optic networks, particularly in FTTx (Fiber to the x) and PON (Passive Optical Networks) deployments, splitters play a central role in distributing the optical signal from a single source to multiple destinations. Whether an optical splitter is combining signals in the upstream direction or dividing signals in the downstream direction, it still introduces the same attenuation to an optical. Testing a splitter or other passive fiber optic devices like switches is little different from testing a patchcord or cable plant using the two industry standard tests, OFSTP-14 for double-ended loss (connectors on both ends) or FOTP-171 for single-ended testing.


  • PoE Switch Cooling Fan

    PoE Switch Cooling Fan

    In contrast, a fan-based PoE switch contains a fan or multiple fans to ensure optimal cooling. The fan expels heat from inside the switch and releases it into the air, which enhances the speed and efficiency of heat dissipation. This cooling method. For years I've been searching for a passively cooled 16-24 port L2 managed POE switch to replace a Cisco SG110-16HP unmanaged POE switch. Seemingly impossible, the need to play with VLANs made me give up on this search and ended up buying a Netgear GS324TP. The main compromise in choosing this was. 1. I replaced them both with a Noctua NF-A4x20 PWM, which is a very quiet fan. Fan cooled models feature an integral PoE Power Splitter which provides power to the DC cooling fan as well as providing power+data for two PoE devices. NEW! NEW! NEW!Need to cut a hole in a piece of furniture and install a small case fan to vent hot air out. 3af/at device, or a ghetto not-IEEE power.

    [PDF Version]
  • Is the power box the same as the electrical distribution box

    Is the power box the same as the electrical distribution box

    While a power panel handles bulk distribution, the distribution panel serves as the final stage of power control before reaching outlets, lights, small appliances, and office equipment. What is a Distribution Board? A distribution board —also called a panelboard, breaker panel, or electrical. If the hardware is identical, why do we have three different names? The answer is simple, but profound: An electrical box is defined by its mission, not its material. A recent discussion among professional electricians perfectly crystallized this definition. If you are. When it comes to electrical systems, terms like “distribution board” and “distribution box” are often used interchangeably, leading to confusion.